Box pump station operating requirements

2016/8/4 14:57:32
Box pump stations have the advantages of energy saving, environmental protection, low noise, and constant water supply pressure. They are becoming more and more common in fire protection applications, so I will explain to you the requirements of box pump stations in operation.
1. The hand pump water pump rotor used before the equipment should be free from friction and stagnation;
2. Use 500V low voltage plug-in meter to test the motor insulation, which should be above 0.5MΩ;
3. The remote pressure gauge sockets 1, 2, 3 (yellow, blue, and red) are connected to terminals 1, 2, and 3, respectively. Or use a multimeter to measure the resistance value of the remote pressure gauge. The maximum resistance value is 1 and 2, the other is 3, the resistance value with 3 is small, and the resistance value with 3 is 2. It is best to check with a multimeter, otherwise the wrong wire will burn the meter;
4. The remote pressure gauge should be installed on the user's pipe network and on the main pipe after the outlet check valve;
5. No damage to control instruments and lines;
6. It is strictly forbidden to move the inverter parameters first after the inverter cabinet is powered;
7. Open the pump exhaust valve to remove the gas;
8. After the system is started for the first time or after maintenance and repair, the water inlet valve should be opened and the outlet valve should be closed when starting; check whether there is leakage in all parts of the system. If any, the leak should be eliminated before starting;
9. First check the pump's steering when the pump is automatic. If it is reverse, reverse any two-phase line of the power supply line; then switch to manually start each pump. If it is reverse, also adjust the pump motor line;
10. Manually start and stop the pumps one by one, and check that there is no abnormal operation of the pumps;
11. After there is no abnormality, put the equipment in the automatic control state.
The main box pump station of our company can also be applied to various industries requiring motor adjustment equipment. It has obvious adjustment accuracy and energy saving effect, fully automatic operation, easy to use and reliable. I believe that the new breakthrough in the intelligence of box pumping stations will bring you a new experience. Zibo Bangyude Water Supply Equipment Co., Ltd. welcomes your call and contact number: 13352210119 Manager Meng 18953368321 Manager Sun.